FSP042-3K13M1

Dimensions : 101.6 x 50.8 x 30.0mm

Watt : 30W

Description

This series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 30-48 watts of continuous output power at convection cooling. They operate at 90-264 VAC input voltage ithout the need of voltage ion, and are suited for medical, information technology and industrial applications. Approval to both EN60601-1 and EN60950-1 Safety Standards improves design-in time and reduces end equipment compliance costs.

Features

  • Medical and ITE approvals
  • Compact size 2” x4” x1.18” Single, dual and triple outputs
  • Wide-range input 90-264 VAC
  • Low earth leakage current Level B emissions
  • RoHS compliant

Model Name FSP042-3K13M1
Wattage 30W
Dimension 101.6mm (L) × 50.8 mm (W) × 30.0mm (H)
Input Electrical Specification Input Voltage 90 ~264 Vdc
Input Frequency 47 ~ 63 Hz
Input Current 0.9A(rms) for100VAC, 0.5A(rms) for240VAC
Leakage Curren 150 µA max. @ 264 VAC,63 Hz
Output Specification Ripple & Noise Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change
Over current protection All outputs protected to short circuit conditions.
Environmental Requirement Temperature Range Operating : -10 to +70℃
Storage :-40 to +85℃
Humidity Operating : 5~95% to % RH, Non-condensing
Storage : 95% to % RH, Non-condensing
MTBF 400,000 hours at fulll load at 25"C ambient, calculated per MIL-HDBK-217F
Safety CSA C22.2,TUV 60950-1,TUV EN 60601-1,UL ES 60601-1,UL 60950-1

Output Voltage and Current Rating

+3.3V +5V +12V1
Ripple-Noise(R-P) mV 100mV 100mV 120mV
Regulation Load % ±3% ±5% ±4%
Output Max.(A) 6A 2A 0.3A
Output Min.(A) 0.8A 0.1A 0A

Notes

1. Safety approvals are for PCB form only. To order unit with cover fitted, change suffix “A” to “C”.

2. The output voltages of a multiple output model may go outside of the stated tolerance when an output load current is out of stated limits. All models may be operated at no-load without damage.

3. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output.

Contact us

 